Desactivar output
Desactiva el relé (OutputsCtrl.switch=close). deviceId acepta UUID o serial del panel; outputId acepta UUID Fusehub o serial del módulo (moduleSeq).
IntegrationKeyX-Integration-Key<token>Clave de integración (fhint_…). Consola Fusehub → Herramientas de desarrollo → API Keys.
site_id*Site IdUUID Fusehub de la sede.
device_id*Device IdUUID Fusehub del panel ALARMA, o su serial (serialNumber / shortSerial / effectiveSerial).
output_id*Output IdUUID Fusehub del output (id del listado) o serial del módulo (moduleSeq).
OK
application/json- response
ok?Oktrueid*IddeviceOutputId*Deviceoutputidswitch*Switchopen o close.
status?string|nulllinkStatus?string|nullcurl -X PUT 'https://api.staging.fusehub.lat/api/integration/v1/sites/string/alarm/devices/string/outputs/string/off'{ "ok": true, "id": "00000000-0000-4000-8000-000000000401", "deviceOutputId": 0, "switch": "close", "status": "close", "linkStatus": "close"}Activar output PUT
Activa el relé (`OutputsCtrl.switch=open`). `deviceId` acepta UUID o serial del panel; `outputId` acepta UUID Fusehub o serial del módulo (`moduleSeq`).
Armar área (compat) PUT
Compat path single-área. Contrato principal: `PUT .../areas/arm` con body `areas` (`areaId` + `ways`). `ways=away` aplica armado total; `ways=stay` aplica armado parcial.